en
de

Deutschland

Italia

España

United Kingdom

United States

Lietuva

Thermion 2 LRF XG
Manual
Thermion 2 LRF XG

Table of contents

Troubleshooting

For technical support please contact support@pulsar-vision.com.

Answers to frequently asked questions about the devices can also be found in the FAQ section.

Possible cause

The Battery Pack is empty

Solution

Charge the Battery Pack

Possible cause

USB cable is damaged.

Solution

Replace USB cable.

 

Possible cause

The external power supply is discharged.

Solution

Charge the external power supply.

Possible cause

Calibration is required.

Solution

Perform image calibration according to Calibration Mode section.

Solution

If the image does not clear after calibration, you need to recalibrate.

Possible cause

The dioptre adjustment range is not enough for your eyesight.

Solution

If you wear glasses with a range of -3/+5, keep glasses on when looking through the eyepiece.

Possible cause

The device was exposed to static electricity during operation.

Solution

After exposure to static electricity, the device may either reboot automatically, or require turning off and on again.

Possible cause

Brightness or contrast level is too low.

Solution

Adjust the brightness or contrast in the Quick Menu.

Possible cause

Dust and condensation are covering the outside or inside optical surfaces.            

Solution

Wipe the outer surface of the objective lens with a soft cotton cloth. Dry the riflescope. Let it stand for four hours in a warm room.

 

Possible cause

The lens is not focused.

Solution

Adjust the image by rotating the lens focus knob.

 
 

Possible cause

The riflescope is not mounted securely or the mount was not fixed with thread sealant.

Solution

Check that the riflescope has been securely mounted.

Make sure you are shooting the same cartridge and load as when the weapon was first zeroed.

Be advised that changes in season, time of day and/or changes in temperature may slightly shift your point of impact. Double checking your zero before hunting is recommended.

 

Possible cause

Wrong settings.              

Solution

Adjust the riflescope according to the Powering on and Image Setting section.

Check the outer surfaces of the objective lenses and eyepiece and, where necessary, wipe away dust, condensation, frost, etc. In cold weather, you can use special anti-fogging coatings (e.g., the same as for corrective glasses).

Possible cause

Password in the riflescope was changed.

Solution

Delete network and connect again inserting the password saved in the riflescope.

 

Possible cause

There are too many Wi-Fi networks in the area where the riflescope is located which may cause signal interference.

Solution

To ensure stable Wi-Fi performance, move the riflescope to an area with few or no Wi-Fi networks.

Solution

Switch the device's Wi-Fi bandwidth.

 

Possible cause

The device has a 5 GHz network enabled, but the smartphone only supports 2.4 GHz.

Solution

Switch the device's Wi-Fi bandwidth to 2.4 GHz.

 

More information on solving problems with connection to Stream Vision 2 by following the link.

Possible cause

Smartphone or tablet is out of range of a strong Wi-Fi signal. There are obstacles between the device and the smartphone or tablet (e.g., concrete walls).

Solution

Relocate smartphone or tablet into the Wi-Fi signal line of sight.

 

More information on solving problems with connection to Stream Vision 2 by following the link.

Possible cause

The object is behind glass, which obstructs thermal vision.

Solution

Remove the glass.

Possible cause

These problems may occur during observation in adverse weather conditions (snow, rain, fog etc.).

 

Solution

The presence of dots is caused by peculiarities of microbolometer or display production technology and is not a defect.

Possible cause

In warm climates, objects in the background of a thermal image heat up differently because of thermal conductivity, generating a high temperature contrast and a sharper thermal image.

In cold climates, objects in the background of a thermal image will cool down to roughly the same temperature, which leads to a greatly reduced temperature contrast and a degraded image quality. This is normal for all thermal imaging devices.

Possible cause

There is an object in front of the receiver or emitter lens preventing signal transmission.

Solution

Make sure that: the lenses are not blocked by your hand or fingers; the lenses are clean.

 

Possible cause

The device is not being held steadily when measuring.

Solution

Keep the device steady when measuring.

 

Possible cause

Distance to the object exceeds 800 m.

Solution

Pick an object at a distance not longer than 800m.

 

Possible cause

Low reflection ratio (for example, tree leaves).

Solution

Pick an object with higher reflection ratio (see point Additional Information in section Laser Rangefinder).

 

Possible cause

Inclement weather conditions (rain, mist, snow).

Possible cause

The Bluetooth module is not turned on.

Solution

Turn on the Bluetooth module according to the instructions (see the Bluetooth section).

 

Possible cause

The Remote control is not activated.

Solution

Activate the remote control according to instructions (see the Remote Control Activation section).

 

Possible cause

The Remote Control is out of range of the device.

Solution

Return to the device coverage area.

 

Possible cause

Remote control battery low.

Solution

Install a new CR2032 battery as follows: unscrew the screws on the rear cover of the Remote Control, remove the cover, install a new battery, and screw the cover with screws.