Zeroing

Zeroing at a temperature close to the riflescope’s operating temperature is recommended.

Step 1. Take a shot

  1. Shooting from a benchrest is recommended.
  2. Set a target at a known distance.
  3. Adjust the riflescope according to the Powering On and Image Setting section.
  4. Select the zeroing profile (see Zeroing Profile  main menu item)
  5. Aim at the center of your target and shoot.

Step 2. Align the reticle with the point of impact

  1. If the point of impact does not match the aiming point, press and hold down the controller button (6) to enter the main menu.
  2. Rotate the controller ring (6) to select the Zeroing  submenu. To confirm the selection, briefly press the controller button (6).
  3. Set the zeroing distance value (see Zeroing  menu item => Add New Distance  submenu).
  4. Confirm the selected zeroing distance value by long pressing the controller button (6).
  5. The Zeroing Parameters Settings  additional menu will appear on the screen.
  6. Cross hairs appear in the center of the display . X and Y coordinates of the cross hairs are in the upper right corner.
  7. Rotate the controller ring (6) to select the icon .
  8. Press the controller button (6) briefly.
  9. Holding the reticle in the aiming point, move the cross hairs by rotating the controller ring (6) until the cross hairs match the point of impact. To switch the direction, briefly press the controller button (6).

One-shot "Freeze Zeroing" function:

Using the Freeze function allows you to make adjustments without the need to hold the rifle precisely at your aiming point – freezing the zeroing screen (refer to Zeroing  menu item => Distance submenu => Zeroing Parameters Settings  submenu => Freeze  submenu or short pressing of the ON/OFF (3) button).

Step 3. Save the coordinates

  1. To save the new reticle position, press and hold the controller button (6). The reticle is aligned with the point of impact and the submenu  exits.
  2. Press and hold the controller button (6) again to exit the zeroing settings menu - the message “Zeroing coordinates saved” appears, confirming the successful operation.
  3. Fire a second shot - now the point of impact and the aiming point must be matched.